A fire risk assessment helps in determining the chances of a fire to occur and the dangers resulted from fire outbreak. Analysing the activities undertaken within the premises; the potential harm of the fire it could cause to the people in, and around the premises is an important issue. The aim of this study was to assess the risk and consequences of a fire outbreak in the trade zone of Nyarugenge. A cross sectional and quantitative methods were used in this study. Fire hazards resulting from readily combustible or highly flammable materials, sources of heat, and people at risk were studied. The likelihood that a fire will occur and the consequences of such a fire on the people in trade zone of Nyarugenge were analysed using a Simple Risk level Estimator. Based on the analysis, 92.71% of the premises had no firefighting equipments in the trade zone 83.33 % of the premises had non-inspected electrical installation and none of them had smoke alarm or heat detectors. Smokers’ materials ranked the highest source of ignition 26% followed by lighting equipments 19%, Cooking Equipment Ranked the third13% followed by Naked flame and misused electrical equipment 12%. The results of the study indicated that the likelihood of a fire in the trade zone of Nyarugenge was high and has significant potential for serious injury or death to occupants.
Published in | American Journal of Health Research (Volume 2, Issue 6) |
DOI | 10.11648/j.ajhr.20140206.12 |
Page(s) | 334-337 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2014. Published by Science Publishing Group |
Fire Risk, Nyarugenge Trade Zone, Likelihood of Fire, Simple Risk Estimator
[1] | MININTER. Police Reminds Public to take Precaution on fire outbreak 2014 Rwandan Police report Available from: http://www.mininter.gov.rw/index.php?id=17&tx_ttnews%5Btt_news%5D=619&cHash=169a5fe7d8af52e6e8249e0ccb477dda |
[2] | Guanquan C, Jinhui W. Study on probability distribution of fire scenarios in risk assessment to emergency evacuation. Reliab Eng Syst Saf. 2012 Mar;99:24–32. |
[3] | Rafi MM, Wasiuddin S, Siddiqui SH. Assessment of fire hazard in Pakistan. Disaster Prev Manag. 2012;21(1):71–84. |
[4] | Grice A. Fire risk fire safety law and its practical application. London; 2009, 1-244. |
[5] | Hasofer AM, Beck VR, Bennetts ID. Risk analysis in building fire safety engineering. Amsterdam; London; 2007; 1-208. |
[6] | Thomson N. Fire hazards in industry. Elsevier; 2001. |
[7] |
RaoSoft, 2014. Online sample size calculator Retrieved 30th May 2014.Available from: |
[8] | British Standards Institution. PAS 79 Fire risk assessment: guidance and a recommended methodology. London: BSI; 2007. |
[9] | Zhang Y. Analysis on Comprehensive Risk Assessment for Urban Fire: The Case of Haikou City. Procedia Eng [Internet]. Elsevier B.V.; 2013 |
[10] | Todd C.S. Specification PA. PAS 79 Fire risk assessment – Guidance and a recommended. 2007;1-120 |
[11] | Woodruff JM. Consequence and likelihood in risk estimation: A matter of balance in UK health and safety risk assessment practice.43(5-6):345–53. |
[12] | Yung D. Principles of Fire Risk Assessment in Buildings, 2008;1-248 |
[13] | Great Britain, Department for Communities and Local Government. Offices and shops. Wether by: Department for Communities and Local Government Publications; 2006. |
[14] | Ballesteros MF, Kresnow M. Prevalence of Residential Smoke Alarms and Fire Escape Plans in the U.S.: Results from the Second Injury Control and Risk Survey (ICARIS-2). Public Health Rep. 2007;122(2):224–31. |
APA Style
Theoneste Ntakirutimana, Rubuga Kitema Felix, Serge Bakire, Wilma Uhorakeye, Donat Tuyihimbaze, et al. (2014). Application of Simple Risk Level Estimator to Assess the Fire Risk in Trade Zone of Nyarugenge. American Journal of Health Research, 2(6), 334-337. https://doi.org/10.11648/j.ajhr.20140206.12
ACS Style
Theoneste Ntakirutimana; Rubuga Kitema Felix; Serge Bakire; Wilma Uhorakeye; Donat Tuyihimbaze, et al. Application of Simple Risk Level Estimator to Assess the Fire Risk in Trade Zone of Nyarugenge. Am. J. Health Res. 2014, 2(6), 334-337. doi: 10.11648/j.ajhr.20140206.12
AMA Style
Theoneste Ntakirutimana, Rubuga Kitema Felix, Serge Bakire, Wilma Uhorakeye, Donat Tuyihimbaze, et al. Application of Simple Risk Level Estimator to Assess the Fire Risk in Trade Zone of Nyarugenge. Am J Health Res. 2014;2(6):334-337. doi: 10.11648/j.ajhr.20140206.12
@article{10.11648/j.ajhr.20140206.12, author = {Theoneste Ntakirutimana and Rubuga Kitema Felix and Serge Bakire and Wilma Uhorakeye and Donat Tuyihimbaze and Osman Ngarukiyintwari}, title = {Application of Simple Risk Level Estimator to Assess the Fire Risk in Trade Zone of Nyarugenge}, journal = {American Journal of Health Research}, volume = {2}, number = {6}, pages = {334-337}, doi = {10.11648/j.ajhr.20140206.12}, url = {https://doi.org/10.11648/j.ajhr.20140206.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajhr.20140206.12}, abstract = {A fire risk assessment helps in determining the chances of a fire to occur and the dangers resulted from fire outbreak. Analysing the activities undertaken within the premises; the potential harm of the fire it could cause to the people in, and around the premises is an important issue. The aim of this study was to assess the risk and consequences of a fire outbreak in the trade zone of Nyarugenge. A cross sectional and quantitative methods were used in this study. Fire hazards resulting from readily combustible or highly flammable materials, sources of heat, and people at risk were studied. The likelihood that a fire will occur and the consequences of such a fire on the people in trade zone of Nyarugenge were analysed using a Simple Risk level Estimator. Based on the analysis, 92.71% of the premises had no firefighting equipments in the trade zone 83.33 % of the premises had non-inspected electrical installation and none of them had smoke alarm or heat detectors. Smokers’ materials ranked the highest source of ignition 26% followed by lighting equipments 19%, Cooking Equipment Ranked the third13% followed by Naked flame and misused electrical equipment 12%. The results of the study indicated that the likelihood of a fire in the trade zone of Nyarugenge was high and has significant potential for serious injury or death to occupants.}, year = {2014} }
TY - JOUR T1 - Application of Simple Risk Level Estimator to Assess the Fire Risk in Trade Zone of Nyarugenge AU - Theoneste Ntakirutimana AU - Rubuga Kitema Felix AU - Serge Bakire AU - Wilma Uhorakeye AU - Donat Tuyihimbaze AU - Osman Ngarukiyintwari Y1 - 2014/10/30 PY - 2014 N1 - https://doi.org/10.11648/j.ajhr.20140206.12 DO - 10.11648/j.ajhr.20140206.12 T2 - American Journal of Health Research JF - American Journal of Health Research JO - American Journal of Health Research SP - 334 EP - 337 PB - Science Publishing Group SN - 2330-8796 UR - https://doi.org/10.11648/j.ajhr.20140206.12 AB - A fire risk assessment helps in determining the chances of a fire to occur and the dangers resulted from fire outbreak. Analysing the activities undertaken within the premises; the potential harm of the fire it could cause to the people in, and around the premises is an important issue. The aim of this study was to assess the risk and consequences of a fire outbreak in the trade zone of Nyarugenge. A cross sectional and quantitative methods were used in this study. Fire hazards resulting from readily combustible or highly flammable materials, sources of heat, and people at risk were studied. The likelihood that a fire will occur and the consequences of such a fire on the people in trade zone of Nyarugenge were analysed using a Simple Risk level Estimator. Based on the analysis, 92.71% of the premises had no firefighting equipments in the trade zone 83.33 % of the premises had non-inspected electrical installation and none of them had smoke alarm or heat detectors. Smokers’ materials ranked the highest source of ignition 26% followed by lighting equipments 19%, Cooking Equipment Ranked the third13% followed by Naked flame and misused electrical equipment 12%. The results of the study indicated that the likelihood of a fire in the trade zone of Nyarugenge was high and has significant potential for serious injury or death to occupants. VL - 2 IS - 6 ER -