The aspiration catheter design requires the good understanding of blood flow, based on a complex analysis of its hemodynamic characteristics. Computational fluid dynamics (CFD) is an important approach in studying the blood flow. In this paper the effect of extra upper holes - designed for the aspiration catheter - on the aspirated fluid pathlines are studied and discussed.
Published in |
American Journal of Biomedical and Life Sciences (Volume 3, Issue 2-2)
This article belongs to the Special Issue Numerical and Experimental Research in Cardiovascular Sciences |
DOI | 10.11648/j.ajbls.s.2015030202.11 |
Page(s) | 1-5 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2015. Published by Science Publishing Group |
Aspiration Catheter, Blood Flow, Computational Fluid Dynamics
[1] | S. Piskin, M. S. Celebi, “Analysis of the effects of different pulsatile inlet profiles on the hemodynamical properties of blood flow in patient specific carotid artery with stenosis”, Computers in Biology and Medicine, vol.43, pp.717-728, 2013 |
[2] | D. I. Zuleger, D. Poulikakos, A. Valavanis, S. S. Kolliadis, “Combining magnetic resonance measurements with numerical simulations – Extracting blood flow physiology information relevant to the investigation of intracranial aneurysms in the circle of Willis”, Int. J. of Heat and Fluid Flow, vol. 31, pp.1032-1039, 2010. |
[3] | B. M. Yun, D. B. EcElhinney, S. Arjunon, L. Mirabella, C. K. Aidun, A. P. Yoganathan, “Computational simulations of flow dynamics and blood damage through a bileaflet mechanical valve scaled to pediatric size and flow”, J. Biomech., vol. 47, pp.3169-3177, 2014. |
[4] | P. Crosetto, P. Reymond, S. Departis, D. Kontaxakis, N. Stergiopulos, A. Quarteroni, “Fluid-structure interaction simulation of aortic blood flow”, Computers & Fluids, vol. 42, pp.46-57, 2011. |
[5] | K. Jozwik, D. Obidowski, “Numerical simulations of the blood flow through vertebral arteries” J. Biomech., vol. 43, pp.177-185, 2010. |
[6] | B. Preim, C. P. Botha, “Visual Computing for Medicine”, 2nd ed., 2014, pp. 665-713. |
[7] | Z. Han-jun, Y. Hong-bing, W. Jian, S. Li, Qing-xiang, L. L. Shi-ying , C. Yun-peng, W. Zheng, Z. Xiao-jiang, Z. Yong, Z. Bin, “Comparison of Diver CE and ZEEK manual aspiration catheters for thrombectomy in ST-segment elevation myocardial infarction”, Chinese Medical Journal, 2009, 122(6): 648-654. |
[8] | F. Burzotta, C. Trani, E. Romagnoli, F. Belloni, G. Biondi-Zoccai, M.A. Mazzari, M. Vita, F. Giannico, B. Garramone, G. Niccoli, A.G. Rebuzzi, R. Mongiardo, G. Schiavoni, F. Crea, A Pilot Study With a New, Rapid-Exchange, “Thrombus-Aspirating Device in Patients With Thrombus-Containing Lesions: The Diver C.E. Study”, Catheterization and Cardiovascular Interventions, 2006, 67: 887–893. |
[9] | D.A. Steinman, “Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries”, Annals of Biomedical Engineering, 2002, 30: 483–497. |
[10] | A.G. Giessen, M. Schaap, F.J.H. Gijsen, H.C. Groen, T. Walsum, N.R. Mollet, J. Dijkstra, F.N. Vosse., W.J. Niessen, P.J. Feyter, A.F.W. Steen, J.J. Wentzel, “3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: a feasibility study, International Journal of Cardiovascular Imaging”, 2010, 26: 781–796. |
[11] | Y.I. Cho, K.R. Kensey, “Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: steady flows”, Biorheology 1991;28:241–62. |
[12] | B.M. Johnston, P.R. Johnston, S. Corney, D. Kilpatrick, “Non-Newtonian blood flow in human right coronary arteries: steady state simulations”, J Biomech 2004;37:709–20. |
[13] | G. Romero, M.L. Martinez, J. Felez, G. Pearce, N.D. Perkinson, “Analysis and design of a thrombectomy device by using simulation techniques”, GProceedings of the IMProVe 2011 International conference on Innovative Methods in Product Design June 15th – 17th, 2011, Venice, Italy. |
[14] | S. Soleimani, G. Dubini, G. Pennati, “Possible Benefits of Catheters With Lateral Holes in Coronary Thrombus Aspiration: A Computational Study for Different Clot Viscosities and Vacuum Pressures”, Artificial Organs 2014, doi: 10.1111/aor.12274 |
APA Style
Sajjad Soleimani. (2015). Visualization of Aspirated Flow Pathlines in a Thrombectomy Catheter with Three Extra Holes: A CFD Study. American Journal of Biomedical and Life Sciences, 3(2-2), 1-5. https://doi.org/10.11648/j.ajbls.s.2015030202.11
ACS Style
Sajjad Soleimani. Visualization of Aspirated Flow Pathlines in a Thrombectomy Catheter with Three Extra Holes: A CFD Study. Am. J. Biomed. Life Sci. 2015, 3(2-2), 1-5. doi: 10.11648/j.ajbls.s.2015030202.11
AMA Style
Sajjad Soleimani. Visualization of Aspirated Flow Pathlines in a Thrombectomy Catheter with Three Extra Holes: A CFD Study. Am J Biomed Life Sci. 2015;3(2-2):1-5. doi: 10.11648/j.ajbls.s.2015030202.11
@article{10.11648/j.ajbls.s.2015030202.11, author = {Sajjad Soleimani}, title = {Visualization of Aspirated Flow Pathlines in a Thrombectomy Catheter with Three Extra Holes: A CFD Study}, journal = {American Journal of Biomedical and Life Sciences}, volume = {3}, number = {2-2}, pages = {1-5}, doi = {10.11648/j.ajbls.s.2015030202.11}, url = {https://doi.org/10.11648/j.ajbls.s.2015030202.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajbls.s.2015030202.11}, abstract = {The aspiration catheter design requires the good understanding of blood flow, based on a complex analysis of its hemodynamic characteristics. Computational fluid dynamics (CFD) is an important approach in studying the blood flow. In this paper the effect of extra upper holes - designed for the aspiration catheter - on the aspirated fluid pathlines are studied and discussed.}, year = {2015} }
TY - JOUR T1 - Visualization of Aspirated Flow Pathlines in a Thrombectomy Catheter with Three Extra Holes: A CFD Study AU - Sajjad Soleimani Y1 - 2015/02/13 PY - 2015 N1 - https://doi.org/10.11648/j.ajbls.s.2015030202.11 DO - 10.11648/j.ajbls.s.2015030202.11 T2 - American Journal of Biomedical and Life Sciences JF - American Journal of Biomedical and Life Sciences JO - American Journal of Biomedical and Life Sciences SP - 1 EP - 5 PB - Science Publishing Group SN - 2330-880X UR - https://doi.org/10.11648/j.ajbls.s.2015030202.11 AB - The aspiration catheter design requires the good understanding of blood flow, based on a complex analysis of its hemodynamic characteristics. Computational fluid dynamics (CFD) is an important approach in studying the blood flow. In this paper the effect of extra upper holes - designed for the aspiration catheter - on the aspirated fluid pathlines are studied and discussed. VL - 3 IS - 2-2 ER -